The Boring Details...

Heating Mode

During heating, a geothermal system absorbs the heat from the ground via the earth loop. The heating cycle starts as cold, liquid refrigerant passes through the water-to-refrigerant heat exchanger (coax, and also the evaporator during heating). The coax is made of copper, and consists of a tube within a tube—water from the loop travels through one tube (the inside tube), refrigerant passes through the other (outer) tube. As the loop fluid flows through the coax, the heat energy transfers from the loop fluid to the refrigerant through the copper wall separating the two. This heat transfer causes the cold liquid refrigerant to turn into a gas. (Unlike water, refrigerant changes from a liquid into a gas at a very low temperature.) The now gaseous refrigerant is sucked into the compressor where it is compressed. After compression, the refrigerant will be very hot (approx. 165° F) and discharged through the reversing valve and into the air coil. The air coil is a radiator-like device that has thin aluminum “fins” attached to the copper refrigerant tubing. The refrigerant passes through the air coil (the condenser during heating). As air from the return air duct system passes over the air coil, heat is released from the refrigerant and absorbed by the cooler air. The result is warm air (typically 95° to 105° F) which is delivered through the duct system by the blower. The refrigerant, now cooled again, passes through the expansion valve (which acts as a flow control), returning to the coax where it can accept more heat from the warmer loop fluid. This process is continuous during the heating mode.

Cooling Mode

During cooling, a geothermal system rejects the heat from the indoor air into the earth loop. The cooling cycle starts as cold, liquid refrigerant passes through the air coil (the evaporator during cooling). As the refrigerant flows through the air coil, the heat energy transfers from the warm return air to the refrigerant. This heat transfer causes the cold liquid refrigerant to turn into a gas. The compressor draws the refrigerant gas, compresses it, and discharges it through the reversing valve. During cooling, the reversing valve is energized, which changes the openings from one port to another, causing the refrigerant flow to go in the opposite direction that it was in the heating mode. (However, the flow to the compressor does not change direction.) After compression, the hot refrigerant passes through the coax (the condenser during cooling). In the coax, the hot refrigerant releases its heat energy to the cool loop fluid through the copper walls. Now cooled and liquified, the refrigerant passes through the expansion valve, back to the air coil. Warm air passing over the cool air coil causes the air to be cooled and dehumidified. This process is continuous during the cooling mode.

Hot Water Mode

Most geothermal units installed in homes have an optional feature called a desuperheater. This component consists of a refrigerant-to-water heat exchanger installed at the discharge of the compressor. The hot gas at this point is in a “superheated” condition. In the desuperheater, the refrigerant releases some of the heat into the cooler water through the copper wall of the desuperheater heat exchanger. A small circulator moves the water from the water heater to the heat pump and back to the water heater. This excess hot gas is available in both the heating and cooling modes. However, there is a greater hot water benefit during cooling because some of the heat that is extracted from the air ends up in the superheat, and is transferred to the water. The amount of hot water generated is a function of the run time of the unit. On very hot days and cold days, the desuperheater may be able to generate the majority of the hot water required for the home due to the long run times of the unit. On milder days when the unit has short duty cycles, the electric elements in the water heater will maintain the desired temperature so there will always be enough hot water. A safety device (sensor) shuts off the circulator for the desuperheater in the event that the water temperature reaches 130°

Florida GeoSource,LLC. · Phone: (386)238-0025 · Fax: (386)238-8688

Home | What is Geothermal Heating & Cooling? | Geothermal Benefits | How it works | Types of Earth Loops | Facts
Typical Install | Applications | Frequently Asked Questions | Contact Us








Site Designed and Hosted by an
Award Winning Design Studio
www.PromptService.com